For cleaning disinfection of medical instruments made of metal, plastic, glass. Aldehyde-free With active agent Glucoprotamin®. Effective against bacteria (incl. TB) and yeasts Limited virucidal according to RKI recommendation of 01/2004 (DVV 2008). RKI-listed (A).

  1. Home
  2. Our Offerings
  3. Sekusept PLUS

Contact Us

Give Us a Call

ECOLAB S.r.l.
Via Trento, 26
20871Vimercate - MB
Italy

Please fill out the contact us form with your details and we will aim to get back to you as soon as possible. A detailed query from your part will help us to be as accurate as possible in our response.

Customer Service:

Telephone: +39 039 6050373 or +39 039 6050374 (8:30 - 17:30)

Fax: +39 039 6057564

Tell Us About Yourself
Where Are you Located?
How Can We Reach You?
What Can We Help You With?

Product Details

For disinfection of medical instruments.

  • Cleans and disinfects medical instruments without aldehyde
  • VAH and RKI listed
  • With innovative active agent Glucoprotamin
Our performance Your advantage
VAH and RKI listed, effective against bacteria (incl. TB) and yeasts, limited virucidal. Protects the user from infection risks through contaminated instruments
Contains Glucoprotamine Unifies the positive properties of the established active agents such as efficacy, biodegradability and user-friendliness
Powerful formulation components Good material compatibility even against sensitive materials such as flexible endoscopes Approved by Olympus. Very good cleaning performance, even with heavily stained instrument types
Low volatility, low foam Suitable for ultrasonic bath applications, pleasant fragrance

Application Areas

For cleaning and disinfection of non-critical medical devices made of metal, glass etc. and for cleaning disinfection of semi-critical and critical medical devices before mechanical reprocessing. For purely manual reprocessing, for terminal disinfection, we recommend using Sekusept aktiv, Sekusept forte and Sekusept forte S.

Usage

Prepare the solution by diluting with water of at least drinking water quality. Place the instruments in the solution immediately after use, ensuring that all surfaces are completely wetted. Clean the instruments following the manufacturer’s instructions, including the mechanism (e.g. brushing, wiping). After the specified contact time, remove the objects from the liquid and rinse with water of at least drinking quality. according to RKI recommendation is to make the solution fresh every day.

Material changes in polycarbonate, polysulfide and acrylic glass with continuous use cannot be ruled out, but can be largely avoided by sufficient rinsing after every application. Not suitable for instruments made from silicone. If flexible endoscopes are chemical-thermally reprocessed mechanically, a thorough rinsing of the endoscope must be done after the disinfecting cleaning, in order to avoid reciprocal action with the products in the machine. For purely manual reprocessing, for terminal disinfection, we recommend using Sekusept aktiv, Sekusept forte and Sekusept forte S.

Service life of unloaded application solution (in covered instrument basin): 14 days

A loaded application solution is to be made fresh every working day according to the RKI recommendation.

Active ingredients contained in 100g:

25g glucoprotamine
Slight color variations in the concentrate do not mean any loss of quality.

Use (after commencement) Shelf life
 
In container
 
until the printed expiration date
 
As a prepared application solution2
 
up to 14 days

1
For a correct storage of environmental hygiene and instrument disinfectants, we request you to observe the following: The original containers (canisters, buckets or bottles) with the disinfectant concentrate (or powder) should be stored at temperatures below 25°C and kept dry and clean. A brief period below or above the given storage temperature (e.g. during transport) will not diminish the effectiveness.
Firmly seal the package after every use. Please also take care that the concentrate remaining in the container is not contaminated when preparing the application solution.

2
Assuming that the prepared application solutions are not affected by organic material and are stored in a clean, closed package or a covered instrument basin.
The containers must be appropriately marked in which the disinfectant solutions are stored, e.g. content, concentration, date, shelf life and batch number. Used and organically contaminated solutions are to be changed at least once per workday as per RKI recommendation.

VAH-listed RKI-listed (A/B)



pikto_instrumente_manuellInstrument disinfection for medical devices
0297


Recommendations

Other interesting products from our range:

Sekusept_aktiv_6kg
Sekusept® aktiv

Complete solution for active cleaning and disinfection

DOWNLOADS

For more product details, pack sizes and all relevant order codes, please download the product brochure below.

Healthcarereceptionarea550x310
PARTNER WITH US

Ecolab Healthcare can partner with you to help increase efficiency, improve outcomes and reduce the risk of Healthcare Associated Infections (HAIs).